Screed for Underfloor Heating in Tidworth

In Tidworth we screed on top of wet underfloor heating, putting the right depth over the pipes and bringing the heat up steadily once it is laid. Locally, heated floors are common because so much of the housing is recent: 24% of Tidworth's homes were built between 2000 and 2014, and the newer houses typically have screeded floors over underfloor heating. Extensions to the post-war semis and terraces add heated floors too, where depth needs planning from the start.

Heated extensions on post-war Tidworth semis

An extension makes underfloor heating straightforward, as the depth can be allowed for on the drawings before anything is built. On a post-war semi or terrace in Tidworth, the new slab is set low enough that insulation, pipes and screed finish level with the existing kitchen or hallway.

The depth over the pipes is the part that cannot be skimped. With liquid screed, cover should be at least 25mm, giving 45 to 50mm in total. Sand and cement wants roughly 45mm on top of the pipes. Because liquid screed surrounds each pipe completely and leaves no air gaps, the room warms faster and the system runs more efficiently. Sand and cement still works where a cement floor is needed, such as a utility area that may get wet.

Fitting pipes is not something we do. Your heating engineer puts them in, tests them under pressure and leaves them pressurised for the whole pour. Our checks before pouring cover the edge strip, membrane and insulation, and anything not right we can supply.

Retrofitting into an existing room is harder. The old floor may have to be dug out to make room for the new layers, or the screed kept as thin as the system allows. In an occupied house, doing one room at a time keeps the rest of the home in use while each new floor dries. Minimum depths are listed in our guide to how thick screed should be.

Repairs and new finishes on Tidworth's heated floors

Many of Tidworth's newer houses already have a screed over underfloor heating, and over time those floors may need levelling or small repairs. A cracked patch, a section cut out to reach a pipe, or a change from carpet to LVT can all mean work on the screed.

A small repair has to match the existing build-up and avoid the pipes. The new section is cut back carefully, filled and finished level with the surrounding floor. Our screed repairs service covers those jobs.

A heated floor that is solid but too uneven for its new finish just needs a thin coat of levelling compound, and levelling a Tidworth floor shows how that works. The heating should be off, and the floor cool, before compound goes down.

After any new pour, commissioning is gradual. With calcium sulphate, the heating can normally go on from about 7 days. Give sand and cement 21 days as a minimum. The temperature is then raised in steps following the system supplier's schedule. Running it hot too soon risks cracking a new heated floor, so it pays to keep the schedule somewhere the whole household can see it.

Underfloor Heating Screed prices in Tidworth

Liquid screed over underfloor heating: £20 to £35 per m² supplied and laid (trade2base, June 2026), so £700 to £1,230 for 35 m². trade2base gives these figures excluding VAT. See our floor screeding cost guide or screed calculator.

Who lays your underfloor heating screed in Tidworth

Underfloor heating pipework running between two rooms before screeding
Underfloor heating pipework running between two rooms before screeding.

K & B Screeding’s own team, led by director Donatas Bardisevicius. Founded 2019, company 12298780.

See what customers say in our Google reviews and on our testimonials page.

Underfloor Heating Screed from Slough to Tidworth

As the crow flies, our yard in Slough is about 48.4 miles from Tidworth, which lies to the west-south-west. Postcodes here include SP9 and SP11, and Amesbury (7 miles), Andover (8.4 miles), Salisbury (13.1 miles) and Devizes (16.2 miles) are close by.

More on underfloor heating screed, part of our screeding services.

FAQs

Underfloor Heating Screed in Tidworth: your questions

How deep does screed need to be over underfloor heating pipes in Tidworth?

A liquid screed should sit 25mm or more above the pipes, for an overall depth of around 45 to 50mm. Sand and cement needs about 45mm over them, which makes the whole floor thicker. Less than that risks cracking above the pipes. We check the levels on site before quoting.

How soon can the underfloor heating run after a pour?

On calcium sulphate you can normally start the system at about 7 days, and the warmth then helps the floor dry out. For sand and cement, hold off for 21 days or longer. In both cases the temperature should rise gradually over several days, following the system supplier's commissioning schedule rather than going straight to full heat.

Can a cracked heated screed in a newer Tidworth house be repaired?

Usually, yes. The damaged area is cut back with care to avoid the pipes, then filled with a compatible screed and finished level. If the crack is due to a wider problem, such as poor cover over the pipes, we will explain that before pricing so you can decide whether to repair or relay.